A filter is not chosen by pool size alone - it is chosen by the flow the turnover needs and the rate the media can take. Sand passes water fast, cartridge slowly, and DE in between, so the same flow calls for very different filter areas.

Enter your pool and the turnover you want, plus the flow your pump actually delivers if you know it, and the calculator returns the media area to match and a verdict on whether that flow is a fit.

Quick answer

A 20,000-gallon pool on an 8-hour turnover needs about 42 gpm: a 2 sq ft sand filter, a 21 sq ft DE filter, or a 111 sq ft cartridge filter.

Calculator

Average of the shallow and deep ends. The pool volume follows from this.
Hours for one full pass of the pool volume. 8 hours is the usual residential default.
The flow your pump delivers at the filter, if you know it. Leave at 0 to skip the flow check.

Quick result

1.8 sq ft (0.17 m²)Recommended filter area
Detailed results
MediaSand
Required flow35.1 gpm (133 L/min)
Filter area (design)1.8 sq ft (0.17 m²)
Smallest that stays in band1.4 sq ft
Oversized (slow end)2.3 sq ft
Rate band15-25 gpm/sq ft
Turnover target8 h

The same flow in every media

The same flow in every media details
Sand1.76 sq ft
Cartridge93.6 sq ft
Diatomaceous earth (DE)17.55 sq ft
The turnover fixes the flow; the media decides how much filter area it takes to pass that flow at a healthy rate.
How this was calculated: Filter area = required flow ÷ media rate, where required flow = gallons ÷ (turnover hours × 60)
Assumptions: Filter areas are the minimum for the turnover flow; a filter matched to a real pump is usually larger · Rate bands are residential planning values: sand 15-25, DE 1.5-2, cartridge 0.25-0.375 gpm per square foot · Volume and surface geometry come from the shared Pool Data Engine · The flow you enter should be the flow at the filter, after pipe and filter losses - not the pump's maximum rating
Planning guidance only. Never restrict the return line to force a filter to perform: a filter that is too small, or a valve set too tight, can starve and damage the pump. Confirm the flow at your filter and the rated flow range printed on the model you plan to buy.
Add the flow your pump delivers to rate this filter against its band - without it, the area shown is the minimum the turnover needs.

Enter valid dimensions or a volume to be able to save this pool.

Next steps

How the filter area is worked out

required flow (gpm) = gallons ÷ (turnover hours × 60); filter area (sq ft) = required flow ÷ media rate

The required flow is the turnover: the whole volume moved across your target window, gallons divided by turnover hours times 60.

Filter area is that flow divided by the media's rate, in gpm per square foot. Sand takes about 20, cartridge about 0.375 and DE about 2, so the areas differ by more than a factor of fifty.

Sizing at the design rate gives the minimum area for the flow. Round up to the next model size: a filter running slightly slower than its band filters finer and needs cleaning less often.

If you enter the flow your pump actually delivers, the calculator also rates that flow against the filter's band - too small, a match, or oversized.

Worked example

A 20,000-gallon pool on an 8-hour turnover, with a pump that delivers 45 gpm at the filter:

1. Required flow = 20,000 ÷ (8 × 60) ≈ 41.7 gpm

2. Sand area = 41.7 ÷ 20 ≈ 2.1 sq ft; DE = 41.7 ÷ 2 ≈ 20.8 sq ft; cartridge = 41.7 ÷ 0.375 ≈ 111 sq ft

3. The pump's 45 gpm on a 2.1 sq ft sand filter = 21.6 gpm/sq ft, inside the 15-25 sand band - a match

The filter that starved the pump

A 24,000-gallon pool runs an 8-hour turnover, so it needs 50 gpm. The owner replaces a tired sand filter with a 100 sq ft cartridge unit, expecting finer water. But at 50 gpm a 100 sq ft cartridge runs at 0.5 gpm per square foot, well past the 0.375 ceiling, so the element loads up in days, the flow collapses and the pump starts to cavitate.

Sized properly, the same pool wants a 2.5 sq ft sand filter, a 25 sq ft DE filter, or a 133 sq ft cartridge. Enter the flow you actually measure and the calculator tells you which side of the band you are on.

Input assumptions

Related calculators

FAQ

What size filter do I need for my pool?
Work from the turnover flow, not the pool size alone. Divide the gallons by the turnover hours times 60 to get the flow in gpm, then divide that flow by the media's rate: about 20 gpm per square foot for sand, 2 for DE and 0.375 for cartridge. Round the result up to the next model size.
Is a bigger filter better?
A larger filter runs slower, filters finer and needs cleaning less often, so a step up from the minimum is usually a good buy. Push too far and you pay for capacity the flow never uses, but on residential pools the cost of oversizing is small next to the cost of choking the media.
Sand, cartridge or DE - which filter is best?
Sand is the cheapest and easiest to live with, cartridge filters finest without backwashing, and DE filters finest of all but needs the most attention. Match the media to the upkeep you want and any local rules on backwash water, then size the area for your flow.
Why does my filter pressure gauge climb so fast?
A gauge that rises quickly usually means the filter is too small for the flow, so the media loads up sooner than it should. Check your flow against the filter's rate band; if it is running past the top of the band, a larger filter or a slower pump speed is the fix.

Sources

See our methodology page for how formulas are selected and reviewed, or start with the pool guides for the numbers in the right order.

Written by PoolForge Editorial Team. Technical review pending - see authors & technical review for the current review status of this page.